Resistivity Meter

MT-RM-220 Resistivity Monitor
Features: MT-RM-220
  • On-line panel mount resisitivity monitor.
  • Display in MΩ.
  • Simulate Function, Non-isolated 4-20mA current output
  • Automatic temperature compensation
.
Technical Parameter:
Sensor input range: 0~18.2MΩ. cm
Accuracy: 1.5% (FS)
Stability: ±2 × 10 ˉ 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25℃
Electrode: 0.05cmˉ1 sanitary grade stainless steel 316L electrode,1/2″ thread
Cable length: 10m or others(5~30m)
Current output: Non-isolated 4-20mA current output
Power supply: AC 220V ±10% 50Hz
Environmental conditions: Temperature: 0~50℃;Humidity: ≤85%RH
Dimensions: 48 × 96 ×100mm (height × width × depth)
Panel cut-out 45X91mm
Installation Cut-out Fit-In
.
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor
.
MT-RM-430 Resistivity Monitor
.
Features: MT-RM-430
  • On-line panel mount resisitivity monitor.
  • Display in MΩ
  • Relay control output, Lo, on, off
  • Automatic temperature compensation
.
Technical Parameter:
Sensor input range: 0~18.2MΩ . cm
Accuracy: 1.5% (FS)
Stability: ±2 × 10 ˉ 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25℃
Electrode: 0.05cmˉ1 sanitary grade stainless steel 316L electrode,1/2″ thread
Cable length: 10m or others(5~30m)
Control output: Relay output, Lo, on, off
Power supply: AC 220V ±10% 50Hz
Environmental conditions: Temperature: 0~50℃;Humidity: ≤85%RH
Dimensions: 48 × 96 ×100mm (height × width × depth)
Panel cut-out 45X91mm
Installation: Cut-out Fit-In
.
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor
.
MT-RM-5220 Resistivity Monitor
.
Features: MT-RM-5220
  • On-line panel mount resisitivity monitor.
  • Display in MΩ
  • Simulate Function, Isolated 4-20mA current output
  • Automatic temperature compensation
.
Technical Parameter:
Sensor input range: 0~18.2MΩ .cm
Accuracy: 1.5% (FS)
Stability: ±2 × 10 ˉ 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25℃
Electrode: 0.05cmˉ1 sanitary grade stainless steel 316L electrode,1/2″ thread
Cable length: 10m or others(5~30m)
Current output: Isolated 4-20mA current output
Power supply: AC 220V ±10% 50Hz
Environmental conditions: Temperature: 0~50℃;Humidity: ≤85%RH
Dimensions: 96 × 96 ×130mm (height × width × depth)
Panel cut-out 92X92mm
Installation: Cut-out Fit-In
.
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor
.
MT-RM-5620 Resistivity Monitor
.
Features: MT-RM-5620
  • On-line panel mount resisitivity monitor.
  • Display in MΩ
  • Simulate Function, Isolated 4-20mA current output
  • Relay control output, Hi, Lo, on, off
  • Automatic temperature compensation
.
Technical Parameter:
Sensor input range: 0~18.2MΩ .cm
Accuracy: 1.5% (FS)
Stability: ±2 × 10 ˉ 3 (FS) / 24h
Display: Back light 3.5-bit LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25℃
Electrode: 0.05 cmˉ1 sanitary grade stainless steel 316L electrode,1/2″ thread
Cable length: 10m or others(5~30m)
Current output: Isolated 4-20mA current output
Control output: Relay control output, Hi, Lo, on, off
Power supply: AC 220V ±10% 50Hz
Environmental conditions: Temperature: 0~50℃;Humidity: ≤85%RH
Dimensions: 96 × 96 ×130mm (height × width × depth)
Panel cut-out: 92X92mm
Installation: Cut-out Fit-In
.
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor
.
MT-CRC-8850 Conductivity/Resistivity Controller
.
Features:
  • On-line panel mount conductivity or resisitivity controller
MT-CRC-8850
  • Display in μS , ppm (TDS) and mS MΩ
  • Simulate Function, Isolated 4-20mA current output
  • Relay control output, Hi, Lo, pulse, off
  • Automatic programmable temperature compensation
  • Dual output option allows temperature and process signal transmission
  • 2X16 character dot matrix LCD
  • NEMA 4X/IP65 enclosure with self-healing window
  • Meets USP requirements
  • Used for conductance, resistance, or TDS signal transmission and display
.
Technical Parameter:
Sensor input range: Conductivity:0.055~400000μS/cm
Resisitivity: 0~18.2MΩ .cm
TDS: 0.023~200000ppm
Accuracy: 1.0% (FS)
Stability: ±2 × 10 ˉ 3 (FS) / 24h
Display: Back light 2X16 character dot matrix LCD
Temperature comp: Automatic thermistor temp compensation, standard temperature: 25℃
(PT1000, -25℃~120℃)
Current output: Isolated 4-20mA current output, fully adjustable and reversible
Relay output: Mechanical SPDT contacts:, Hi, Lo, Pulse, Of
Max 400 pulses/min
Open-collector output: Hi, Lo, Pulse, Off
Max 400 pulses/min
Communication Output: RS-485 serial port
Power supply: DC 18~36V
Environmental conditions: Temperature: 0~50℃;Humidity: ≤85%RH
Dimensions: 96 × 96 ×45mm (height × width × depth)
Panel cut-out 92X92mm
Installation: Cut-out Fit-In
.
Application:
  • RO/DI system monitor
  • Cooling water monitor
  • Industrial water process monitor
  • Desalinization monitor
  • Water quality monitor
  • Environmental study (TDS)
  • Leak detection
  • Chemical concentration